1 Ladder Program Instructions

1.1.7 RISING PULSE Instruction (ON-PLS)

1-12

„

Program Example

When IB00001 turns ON from OFF, MB000101 turns ON and stays ON during 1 scan.
MB000100 is used to store the previous value of IB00001.

Register status of Rising pulse instruction is shown in Table 1.1.

Note: Case of Program Example, the instruction is used not for rise detec-

tion of MB000100 but is used for rise detection of IB00001.
MB000100 is used only for storing the previous value of IB00001.

Table 1.1 Register Status with Rising Pulse Instruction

Input

Result

IB00001

MB000100

(Previous value of

IB00001)

MB000100

(IB00001 stored)

MB000101

OFF

OFF

OFF

OFF

OFF

ON

OFF

OFF

ON

OFF

ON

ON

ON

ON

ON

OFF

IB00001

1 scan

1 scan

MB000100

MB000101

ON

OFF

ON

OFF

ON

OFF

Advertising