1 Ladder Program Instructions

1.7.12 LINEAR ACCELERATOR/DECELERATOR 2 Instruction (SLAU)

1-162

Real Number Type Operation

MF00200 to MF00218 are used for the parameter table.

Note: Please note the following when you use integer type SLAU instruc-

tion.
Please do not change input value (VI) before reaching input value
(VI) (de-and acceleration inside).
When input value (VI) is changed in the de-and acceleration, over-
shooting/undershoot might be generated. (Refer to the figure below)
Please make the application program when you change input value
(VI) in the de-and acceleration by either the undermentioned.

• Please use real type SLAU instruction.
• Please use the LIMIT instruction together when you use inte-

ger SLAU instruction. The output value of integer type
SLAU instruction is limited, and that is, please assume the
output value of the LIMIT instruction to be a input value of
the LIMIT instruction, and limit overshooting/undershoot.

I will encourage the use of one real type SLAU instruction
from the easiness of making the application program.

Deviation input value

Head address of parameter table
SLAU output value

BT

Speed

(V)

VI

(100%)

0

Acceleration

Deceleration

S-curve
section

Straight
line area

S-curve
section

AAT

AT-AAT

AT

AT + AAT

BT + BBT

AAT

S-curve
section

Straight
line area

S-curve
section

BBT

BT-BBT

BBT

Acceleration
start

Acceleration
completed

Deceleration
start

Deceleration
completed

Time
(t)

Advertising