1.8 Table Data Manipulation Instructions

1-169

1

„

Format

„

Parameter

* Possible to omit.

„

Program Example

From the table defined as TABLE1, with DW00010 to DW00015 as a parameter table, area
(element type is integer type) from the starting table element position to the end position are
stored in block form in the data from MW00100.

Parameter Name

Setting

Table Name

Table name

Write Data

• Register address (except for # and C registers)
• Register address with subscript

Parameter

• Register address
• Register address with subscript

[Output]*

• Any integer type register (except for # and C registers)
• Any integer type register with subscript
• Subscript register

[Status]*

• Any bit type register (except for # and C registers)
• Any bit type register with subscript

Symbol: TBLBW
Full Name: Table Block Write
Category: TABLE
Icon:

Advertising