C.4 calibration object (0x65), Calibration object (0x65), See table c-6 – Emerson Process Management MICRO MOTION 2400S User Manual

Page 155

Advertising
background image

Configuration and Use Manual

147

Device Profile

D

e

vice Pr

ofile

In

de
x

Displa

y Codes

Men

u

s

C.4

Calibration Object (0x65)

7

Enable gas
standard volume

BOOL

Set

NV

Enable or disable gas
standard volume
measurement

(3)

• 0 = Disabled
• 1 = Enabled

8

Gas standard
volume low flow
cutoff

REAL

Set

NV

Value below which gas
standard volume flow will
be reported as 0

9

Reset gas
standard volume
total

USINT

Set

V

Resets the gas standard
volume total

• 1 = Reset

10

Reset gas
standard volume
inventory

USINT

Set

V

Resets the gas standard
volume inventory

• 1 = Reset

(1) Service code 0x4B.
(2) Service code 0x4C.
(3) If gas standard volume measurement is enabled, liquid volume measurement is disabled, and vice versa.

Table C-6

Calibration Object (0x65) – Instance 1

Attrib
ID

Name

Data type

Service

Mem

Description

Comments

1

Flow calibration
factor

REAL

Set

NV

6-character flow
calibration factor

2

Temperature
coefficient for
flow

REAL

Set

NV

4-character temperature
coefficient

3

Zero time

UINT

Set

V

Duration of the zero
calibration procedure

Unit = seconds

4

Zero standard
deviation

REAL

Get

NV

The standard deviation
result of the zero
calibration service

5

Zero offset

REAL

Set

NV

The offset result of the
zero calibration service

6

Calibration failed
value

REAL

Get

V

The value of the
calibration parameter if
one of the calibration
services fails

7

K1

REAL

Set

NV

Density calibration
constant 1

Unit = milliseconds

8

K2

REAL

Set

NV

Density calibration
constant 2

Unit = milliseconds

9

FD

REAL

Set

NV

Flowing density
calibration constant

Unit = milliseconds

10

K3

REAL

Set

NV

Density calibration
constant 3

Unit = milliseconds

11

K4

REAL

Set

NV

Density calibration
constant 4

Unit = milliseconds

12

D1

REAL

Set

NV

The line-condition density
of D1 calibration service

Unit = g/cm

3

Table C-5

Gas Standard Volume Object (0x64) – Instance 1 continued

Attrib
ID

Name

Data type

Service

Mem

Description

Comments