Emerson Process Management MICRO MOTION 2400S User Manual

Page 89

Advertising
background image

Configuration and Use Manual

81

Optional Configuration

Requ

ired Co

nfi
g

u

ratio

n

Op

ti

on
al

Co

nfi
g

u

rati

o

n

Using the T

rans

m

itte

r

Us
ing a De

vice

Net T

o

ol

Requ

ired Co

nfi
g

u

ratio

n

Op

ti

on
al

Co

nfi
g

u

rati

o

n

Using the T

rans

m

itte

r

Us
ing a De

vice

Net T

o

ol

Requ

ired Co

nfi
g

u

ratio

n

Op

ti

on
al

Co

nfi
g

u

rati

o

n

Using the T

rans

m

itte

r

Us
ing a De

vice

Net T

o

ol

Requ

ired Co

nfi
g

u

ratio

n

Op

ti

on
al

Co

nfi
g

u

rati

o

n

Using the T

rans

m

itte

r

Us
ing a De

vice

Net T

o

ol

Figure 8-3

Configuring the enhanced density application – DeviceNet tool

Set transmitter temperature measurement unit to
match curve unit
· For standard curves, see Table 8-16
· For custom curves, see the information provided

with the curve

Set transmitter density measurement unit to
match curve unit
· For standard curves, see Table 8-16
· For custom curves, see the information provided

with the curve

Class: Analog Input Point Object (0x0A)
Instance: 4
Attribute ID: 102
Value: See Table 6-6
Service: Set

Set derived variable
· For standard curves, use Mass Conc (Dens)
· For custom curves, see the information provided

with the curve

Class: Enhanced Density Object (0x64)
Instance: 1
Attribute ID: 15
Data type: USINT
Value: See Table D-17
Service: Set

Class: Analog Input Point Object (0x0A)
Instance: 3
Attribute ID: 102
Value: See Table 6-5
Service: Set

Specify the active curve

Class: Enhanced Density Object (0x64)
Instance: 1
Attribute ID: 16
Data type: USINT
Value: 0 – 5
Service: Set

Enable the enhanced density application

Class: Enhanced Density Object (0x64)
Instance: 1
Attribute ID: 39
Data type: BOOL
Value:
· 0: Disabled
· 1: Enabled
Service: Set