C.9 enhanced density object (0x6a), Enhanced density object (0x6a), E table c-11 – Emerson Process Management MICRO MOTION 2400S User Manual

Page 171

Advertising
background image

Configuration and Use Manual

163

Device Profile

D

e

vice Pr

ofile

In

de
x

Displa

y Codes

Men

u

s

C.9

Enhanced Density Object (0x6A)

7

CTL

REAL

Get

V

Current value

8

API reference
temperature

REAL

Set

NV

The reference
temperature to use in the
API calculations

9

API thermal
expansion
coefficient

REAL

Set

NV

The thermal expansion
coefficient to use in the
API calculations

10

API 2540 CTL
table type

USINT

Set

NV

The table type to use in
the API calculations

• 17 = Table 5A
• 18 = Table 5B
• 19 = Table 5D
• 36 = Table 6C
• 49 = Table 23A
• 50 = Table 23B
• 51 = Table 23D
• 68 = Table 24C
• 81 = Table 53A
• 82 = Table 53B
• 83 = Table 53D
• 100 = Table 54C

11

Reset API
reference
volume total

USINT

Set

V

Resets the API reference
volume total

• 1 = Reset

12

Reset API
reference
volume
inventory

USINT

Set

V

Resets the API reference
volume inventory

• 1 = Reset

(1) Service code 0x4B.
(2) Service code 0x4C.

Table C-11

Enhanced Density Object (0x6A) – Instance 1

Attrib
ID

Name

Data type

Service

Mem

Description

Comments

1

Density at
reference

REAL

Get

V

Current value

2

Density (fixed
SG units)

REAL

Get

V

Current value

3

Standard
volume flow rate

REAL

Get

V

Current value

4

Standard
volume total

REAL

Get
Reset

(1)

V

Current value

5

Standard
volume
inventory

REAL

Get
Reset

(2)

V

Current value

6

Net mass flow
rate

REAL

Get

V

Current value

7

Net mass flow
total

REAL

Get
Reset

(3)

V

Current value

Table C-10

API Object (0x69) – Instance 1 continued

Attrib
ID

Name

Data type

Service

Mem

Description

Comments

Advertising