Clips. see figure 4-1, Warning – Emerson Process Management MICRO MOTION 2400S User Manual

Page 27

Advertising
background image

Configuration and Use Manual

19

Connecting with ProLink II or Pocket ProLink Software

St
a

rt

u

p

Usin

g P

ro

L

in

k II

T

ransmitter User

Interface

Be
fo

re
Y

o

u

Begin

St
a

rt

u

p

Usin

g P

ro

L

in

k II

T

ransmitter User

Interface

Be
fo

re
Y

o

u

Begin

St
a

rt

u

p

Usin

g P

ro

L

in

k II

T

ransmitter User

Interface

Be
fo

re
Y

o

u

Begin

St
a

rt

u

p

Usin

g P

ro

L

in

k II

T

ransmitter User

Interface

Be
fo

re
Y

o

u

Begin

Figure 4-1

Serial port connections to service port clips

3. Start ProLink II or Pocket ProLink. In the Connection menu, click

Connect to Device

. In the

screen that appears, specify:

Protocol

:

Service Port

COM Port

: as appropriate

No other parameters are required.

4. Click

Connect

. The software will attempt to make the connection.

5. If an error message appears:

a.

Swap the leads between the two service port clips and try again.

b.

Ensure that you are using the correct COM port.

c.

Check all the wiring between the PC and the transmitter.

d. Verify the RS-485 to RS-232 signal converter.

WARNING

Removing the transmitter housing cover in a hazardous area can cause an
explosion.

Because the transmitter housing cover must be removed to connect to the service
port clips, the service port clips should be used only for temporary connections,
e.g., for configuration or troubleshooting purposes.

When the transmitter is in an explosive atmosphere, use a different method to
connect to your transmitter.

Service port clips

RS-485 to RS-232
signal converter

25-pin to 9-pin serial port
adapter (if necessary)

RS-485/A

RS-485/B

PC