3 external temperature compensation, External temperature compensation, Section 9.3 – Emerson Process Management MICRO MOTION 2400S User Manual

Page 93: Vicenet tool, see figure 9-2

Advertising
background image

Configuration and Use Manual

85

Pressure Compensation and Temperature Compensation

Me

asu

reme

nt P

er
form

anc

e

Defaults

T

rou
b

lesho

o

ti

ng

Compensation

Figure 9-2

Configuring pressure compensation with a DeviceNet tool

9.3

External temperature compensation

External temperature compensation can be used with the petroleum measurement application or the
enhanced density application.

Note: The external temperature value is used only for calculation of the derived variable in enhanced
density applications or the CTL value in petroleum measurement applications. The temperature value
from the sensor is used for all other calculations that require a temperature value.

Set flow calibration

pressure

Set flow factor

Class: Calibration Object (0x65)
Instance: 1
Attribute ID: 32
Data type: REAL
Service: Set

Set density factor

Class: Calibration Object (0x65)
Instance: 1
Attribute ID: 31
Data type: REAL
Service: Set

Class: Calibration Object (0x65)
Instance: 1
Attribute ID: 30
Data type: REAL
Service: Set

Enable pressure

compensation

Class: Calibration Object (0x65)
Instance: 1
Attribute ID: 27
Data type: BOOL
Value:
· 0 = disabled
· 1 = enabled

Set pressure unit

Class: Calibration Object (0x65)
Instance: 1
Attribute ID: 29
Value: See Table 6-7
Service: Set

Yes

Use static

pressure value?

No

Set up output

assembly

(2)

Class: Calibration Object (0x65)
Instance: 1
Attribute ID: 28
Data type: REAL
Service: Set

Set static value

(1) Pressure measurement unit must

be configured to match pressure unit
used by external device. See
Section 6.3
.

(2) See Section 9.4.