Emerson Process Management MICRO MOTION 2400S User Manual

Page 159

Advertising
background image

Configuration and Use Manual

151

Device Profile

D

e

vice Pr

ofile

In

de
x

Displa

y Codes

Men

u

s

14

Alarm status 3

UINT

Get

V

A collection of status bits

• 0x0001 = Not used
• 0x0002 = Power reset
• 0x0004 = Transmitter

initializing

• 0x0008 =

Transmitter/sensor
communications fault
(A28)

• 0x0010 = Not used
• 0x0020 = Not used
• 0x0040 = Not used
• 0x0080 =

Transmitter/sensor
communications fault
(A26)

• 0x0100 = Calibration

failed

• 0x0200 = Calibration

failed: Low

• 0x0400 = Calibration

failed: High

• 0x0800 = Calibration

failed: Noisy

• 0x1000 = Transmitter

failed

• 0x2000 = Data loss
• 0x4000 = Calibration

in progress

• 0x8000 = Slug flow

Table C-7

Diagnostics Object (0x66) – Instance 1 continued

Attrib
ID

Name

Data type

Service

Mem

Description

Comments

Advertising