Emerson Process Management MICRO MOTION 2400S User Manual

Page 34

Advertising
background image

26

Micro Motion

®

Model 2400S Transmitters for DeviceNet

™

Required Transmitter Configuration

Figure 6-1

Sample calibration tags

Flow calibration values

Two factors are used to define flow calibration:

•

The flow calibration factor, which is a 6-character string (five numbers and a decimal point)

•

The temperature coefficient for flow, which is a 4-character string (three numbers and a
decimal point)

These values are concatenated on the sensor tag, but different labels are used for different sensors. As
shown in Figure 6-1:

•

For T-Series sensors, the value is called the FCF value.

•

For other sensors, the value is called the Flow Cal value.

Table 6-1

Sensor calibration parameters

Parameter

Sensor type

T-Series

Other

K1

✓

✓

K2

✓

✓

FD

✓

✓

D1

✓

✓

D2

✓

✓

Temp coeff (DT)

(1)

(1) On some sensor tags, shown as TC.

✓

✓

Flowcal

✓

(2)

(2) See the section entitled “Flow calibration values.”

FCF

✓

FTG

✓

FFQ

✓

DTG

✓

DFQ1

✓

DFQ2

✓

Other sensors

19.0005.13

0.0010
0.9980

12502.000
14282.000

4.44000

310

12500142864.44

T-Series

Advertising