To reset an individual totalizer or inventory:

1. Click

ProLink > Totalizer Control

or

ProLink > ED Totalizer Control

(if the enhanced

density application is enabled).

2. Click the appropriate button (e.g.,

Reset Mass Total

,

Reset Volume Inventory

,

Reset Net

Mass Total

).

With a DeviceNet tool

Using a DeviceNet tool, three methods are available for totalizer and inventory control:

EDS – If you have imported the EDS into your DeviceNet tool, you can perform the following
functions from the EDS user interface:

-

Reset mass totalizer

-

Reset mass inventory

-

Reset liquid volume totalizer

-

Reset liquid volume inventory

-

Reset API reference volume total

-

Reset API reference volume inventory

-

Reset gas standard volume totalizer

-

Reset gas standard volume inventory

-

Reset ED standard volume total

-

Reset ED net mass total

-

Reset ED net volume total

-

Reset ED standard volume inventory

-

Reset ED net mass inventory

-

Reset ED net volume inventory

Explicit write – Using a Set, a Reset Total, or a Reset Inventory service, you can perform the
functions listed in Table 7-8.

Output assemblies – Five output assemblies are provided, supporting the functions listed in
Table 7-9. See the manual entitled Micro Motion Model 2400S Transmitters for DeviceNet:
Device Profile
for detailed information.

Table 7-8

Totalizer and inventory control with a DeviceNet tool using explicit write

To accomplish this

Use this device profile data

Stop all totalizers and inventories

Analog Input Point Object (0x0A)
Instance: 0
Attribute ID: 100
Service: Set
Value: 0

Start all totalizers and inventories

Analog Input Point Object (0x0A)
Instance: 0
Attribute ID: 100
Service: Set
Value: 1

Reset all totalizers

Analog Input Point Object (0x0A)
Instance: 0
Attribute ID: 101
Service: Set
Value: 1