2 configuration procedure, Configuration procedure – Emerson Process Management MICRO MOTION 2400S User Manual

Page 85

Advertising
background image

Configuration and Use Manual

77

Optional Configuration

Requ

ired Co

nfi
g

u

ratio

n

Op

ti

on
al

Co

nfi
g

u

rati

o

n

Using the T

rans

m

itte

r

Us
ing a De

vice

Net T

o

ol

Requ

ired Co

nfi
g

u

ratio

n

Op

ti

on
al

Co

nfi
g

u

rati

o

n

Using the T

rans

m

itte

r

Us
ing a De

vice

Net T

o

ol

Requ

ired Co

nfi
g

u

ratio

n

Op

ti

on
al

Co

nfi
g

u

rati

o

n

Using the T

rans

m

itte

r

Us
ing a De

vice

Net T

o

ol

Requ

ired Co

nfi
g

u

ratio

n

Op

ti

on
al

Co

nfi
g

u

rati

o

n

Using the T

rans

m

itte

r

Us
ing a De

vice

Net T

o

ol

Table 8-14 summarizes these options.

8.13.2

Configuration procedure

The API configuration parameters are listed and defined in Table 8-15.

To configure the petroleum measurement application:

Using ProLink II, see Figure B-3.

Using a DeviceNet tool, see Table C-10.

Note: This functionality is not available via the display menus.

Table 8-14

API reference temperature tables

Table

CTL
derivation
method

Base temperature

Density unit and range

Degrees API

Base density

Relative density

5A

Method 1

60 °F, non-configurable

0 to +100

5B

Method 1

60 °F, non-configurable

0 to +85

5D

Method 1

60 °F, non-configurable

–10 to +40

23A

Method 1

60 °F, non-configurable

0.6110 to 1.0760

23B

Method 1

60 °F, non-configurable

0.6535 to 1.0760

23D

Method 1

60 °F, non-configurable

0.8520 to 1.1640

53A

Method 1

15 °C, configurable

610 to 1075 kg/m

3

53B

Method 1

15 °C, configurable

653 to 1075 kg/m

3

53D

Method 1

15 °C, configurable

825 to 1164 kg/m

3

Reference temperature

Supports

6C

Method 2

60 °F, non-configurable

60 °F

Degrees API

24C

Method 2

60 °F, non-configurable

60 °F

Relative density

54C

Method 2

15 °C, configurable

15 °C

Base density in kg/m

3

Table 8-15

API parameters

Variable

Description

Table type

Specifies the table that will be used for reference temperature and reference density unit. Select
the table that matches your requirements. See API reference tables.

User defined TEC

(1)

(1) Configurable if Table Type is set to 6C, 24C, or 54C.

Thermal expansion coefficient. Enter the value to be used in CTL calculation.

Temperature units

(2)

(2) In most cases, the temperature unit used by the API reference table should also be the temperature unit configured for the transmitter

to use in general processing. To configure the temperature unit, see Section 6.3.

Read-only. Displays the unit used for reference temperature in the reference table.

Density units

Read-only. Displays the unit used for reference density in the reference table.

Reference
temperature

Read-only unless Table Type is set to 53x or 54x. If configurable:

• Specify the reference temperature to be used in CTL calculation.
• Enter reference temperature in °C.