Read local inputs iw0, Ez800/ezd control commands – Eaton Electrical PROFIBUS-DP EZ204-DP User Manual

Page 104

Advertising
background image

For more information visit: www.EatonElectrical.com

EZ800/EZD Control Commands

MN05013001E

100

Read local inputs IW0
This command string enables you to read the local inputs of

the EZ800/EZD. The relevant input word is stored in Intel

format.
Telegram structure

Table 45: Byte 5 to 6: Data 1 to 2

Byte

Meaning

Value (hex), sent by

Master

Slave

0

Toggle byte

J

page 94

1

Command: Read

91

Response:

Read successful

C2

Command

rejected

C0

2

Len

02

02

3

Type

01

01

4

Index

00

00

5

Data 1 (Low Byte)

00

J

Table 45

6

Data 2 (High Byte)

00

J

Table 45

7 – 8

Data 3 – 4

00

00

Data 1 Bit 7

6

5

4

3

2

1

0

I1

0/1

I2

0/1

..

..

I8

0/1

Data 2 Bit 7

6

5

4

3

2

1

0

I9

0/1

I10

0/1

..

..

I16

0/1