Local inputs: i1 - i16, Local inputs: i1 – i16, Control commands for ez700 – Eaton Electrical PROFIBUS-DP EZ204-DP User Manual

Page 58

Advertising
background image

For more information visit: www.EatonElectrical.com

Control commands for EZ700

MN05013001E

54

Local inputs: I1 – I16
This command string enables you to read the local inputs of

the EZ700 basic unit. The relevant input word is stored in Intel

format.
Telegram structure

Byte

Meaning

Value (hex), sent by

Master

Slave

0

Toggle byte

J

page 44

1

Command: Read

88

Response:

Read successful

C2

Command

rejected

C0

1)

2

Len

02

02

3

Type

84

84

4

Index

00

00

5

Data 1 (Low Byte)

00

J

Table 13

6

Data 2 (High Byte)

00

J

Table 13

7 – 8

Data 3 – 4

00

00

1) Possible causes J page 91