Setting the profibus-dp station address, Device operation – Eaton Electrical PROFIBUS-DP EZ204-DP User Manual

Page 30

Advertising
background image

For more information visit: www.EatonElectrical.com

Device Operation

MN05013001E

26

Setting the PROFIBUS-DP
station address

Every PROFIBUS-DP station requires an unambiguous

address in the PROFIBUS-DP structure. There are two ways

of setting the PROFIBUS-DP addresses on the EZ204-DP:
• Using the integrated display and keypad on the EZ or EZD

basic unit

• Using EZSoft on the PC.

Address range: 001 to 126

Setting the address on the basic unit with a display
Requirements:
• The basic unit (EZ700, EZ800 or EZD) and the EZ204-DP

expansion unit must be fed with power.

• The basic unit has been unlocked (no password activated).
• The basic unit has a valid operating system version

(J page 15).

• The basic unit must be in STOP mode.
• The EZ204-DP is not communicating with the PROFIBUS-

DP master (Bus LED is off).