Analog value comparators/threshold comparators, A1 – a16, Analog value comparators/threshold – Eaton Electrical PROFIBUS-DP EZ204-DP User Manual

Page 55: Comparators: a1 – a16, Read/write image data

Advertising
background image

Read/write image data

For more information visit: www.EatonElectrical.com

MN05013001E

51

Analog value comparators/threshold comparators:
A1 – A16
The following commands are used to read the logic state of

the individual analog value comparators A1 to A16.
Telegram structure

Table 10: Byte 5 to 6: Data 1 to 2

Byte

Meaning

Value (hex), sent by

Master

Slave

0

Toggle byte

J

page 44

1

Command: Read

88

Response:

Read successful

C2

Command

rejected

C0

1

2

Len

01

01

3

Type

8C

8C

4

Index

00

00

5

Data 1 (Low Byte)

00

J

Table 10

6

Data 2 (Low Byte)

00

J

Table 10

7 – 8

Data 3 – 4

00

00

1) Possible causes J page 91

Data 1 Bit 7

6

5

4

3

2

1

0

A1

0/1

A2

0/1

...

...

A8

0/1

Data 2 Bit 7

6

5

4

3

2

1

0

A9

0/1

A10

0/1

...

...

A16

0/1