Data exchange procedure – Eaton Electrical PROFIBUS-DP EZ204-DP User Manual

Page 51

Advertising
background image

Data exchange procedure

For more information visit: www.EatonElectrical.com

MN05013001E

47

Table 8:

Index 2 – Winter time

(only valid if Area = “Rule” selected)

Switching rule bit array

Byte

Contents

Value (hex)

4

Data 1

Area = Rule

01

5 – 8

Data 2 – 5

Winter time

switching rule

J

Table 9

J

Please also read the detailed description in the EZ500/700

manual (MN05013003E).
The following table shows the composition of the

corresponding data bytes.