Analog value comparator/threshold comparator, A1 – a16, Read/write function block data – Eaton Electrical PROFIBUS-DP EZ204-DP User Manual

Page 77

Advertising
background image

Read/write function block data

For more information visit: www.EatonElectrical.com

MN05013001E

73

Analog value comparator/threshold comparator:
A1 – A16

Telegram structure

Byte

Meaning

Value (hex), sent by

Master

Slave

0

Toggle byte

J

page 44

1

Command:

Read

89

Write

8D

Response:

Read successful

C2

Write successful

C1

Command

rejected

C0

1

2

Type

8D

8D

3

Instance

2

00 – 0F

00 – 0F

4

Index

Table 24

5 – 8

Data 1 – 4

depending on index J Table 25

1) Possible causes J page 91
2) EZ provides 16 analog comparators A1 to A16 for use as

required. These can be addressed using the instance (0 – F).