Read/write image data

General notes on working with image data

When writing to image data, it must be remembered that an

image (e.g. inputs, outputs,... ) used in the EZ700/EZ800/EZD

program is also written cyclically by the actual program. The

only image data that is unchanged is the data that is not used

in the program and is therefore not overwritten in the program

cycle. This operating principle also means that an image

written via EZ-LINK, such as output data is only then output at

the physical outputs of the EZ700/EZ800/EZD when the

control relay is in Run mode.

J

Please also observe the relevant description of possible

image data provided in the EZ500/700 manual

(MN05013003E) or in the EZSoft Help.
The latest edition of the manual is available as a PDF file

from the Internet at:

www.EatonElectrical.com.

Search

Term: MN05013003E.

Read

inputs

Image data

written

Write

outputs

EZ/EZD

Program cycle

(0 ... 20 ms)

System time

EZ-LINK

Interrupt function

(every 12 or 25 ms)