Read/write function block data – Eaton Electrical PROFIBUS-DP EZ204-DP User Manual

Page 133

Advertising
background image

Read/write function block data

For more information visit: www.EatonElectrical.com

MN05013001E

129

Table 62: Index 0 – Bit IO

Table 63: Index 1 - Mode

J

The data for index 2 and 3 is transferred as a 32-bit value in

Intel format (Data 1 – Low Byte .. Data 2 - High Byte).

Bit 7 6 5 4 3

2

1

0

FB input Data 1

– – – – –

T

1

FB output Data 3

– – – – –

E3

2

E2

3

E1

4

1) Transfer of the source address specified at I1 to the target

address specified at I2 on rising edge.

Error outputs

2) Status 1 if the number of elements exceeds the source or target

range.

3) Status 1 if the source and target range overlap.
4) Status 1 if the source or target range are outside of the

available marker range (offset error)

Data 1
(hex)

Operating mode

00

INI: Initializes the target range with a byte value stored

at the source address.

01

CPY: Copies a data block from a source to a target

range. Data block size is specified at NO.