Reading receive data network rn1 .. rn32, Send data network sn1 .. sn32, Reading receive data network rn1 – Eaton Electrical PROFIBUS-DP EZ204-DP User Manual

Page 118: Rn32/send data network sn1 .. sn32, Ez800/ezd control commands

Advertising
background image

For more information visit: www.EatonElectrical.com

EZ800/EZD Control Commands

MN05013001E

114

Value (hex), sent by

Master

Slave

0

Toggle byte

J

page 94

1

Command: Read

91

Response:

Read successful

C2

Command

rejected

C0

2

Len

04

04

3

Type

For RN1 – RN32: 08
For SN1 – SN32: 0A

4

Index

01 – 08

1

01 – 08

1

5 – 8

Data 1 – 4

00

J

Table 50

1) Corresponds to NET-ID

Reading receive data network RN1 .. RN32/send data
network SN1 .. SN32
EZ-NET allows a point-to-point connection to be implemented

between the individual NET stations. The RN and SN data are

used for the data exchange (see the EZ800 manual and EZD

manual).
The latest editions of these manuals are available as PDF files

from the Internet at:

www.EatonElectrical.com.

EZ800 manual

search term: MN05013004E. EZD manual search term:

MN05013005E.

J

The RN SN data of the local device (Index = 0) to which the

EZ204-DP is fitted cannot be scanned. In this case the

command would be denied with the 0C

hex

signal.

Byte

Meaning

Advertising