“Outputs 3 bytes” module: operating mode, R9

For more information visit: www.EatonElectrical.com

MN05013001E

39

Table 3:

Byte 0: Operating mode

0 = status “0”, 1 = status “1”
Explanation

Value 34

hex

= 00110100

bin

:

This value sets the EZ/EZD status from STOP to RUN. It is

only interpreted as a command and therefore does not permit

an additional transfer of data. The index value 14

hex

must be

used in this situation.
Value 44

hex

= 01000100

bin

:

This value sets the EZ/EZD status from RUN to STOP. It is

also used only as command and it therefore works in the same

way as the RUN command.

EZ/EZD operating mode

Bit

7

6

5

4

3

2

1

0

Index for setting the basic unit to the safety

state

0

0

0

0

0

0

0

0

Index for transferring valid data

0

0

0

1

0

1

0

0

RUN command

0

0

1

1

0

1

0

0

STOP command

0

1

0

0

0

1

0

0