Read/write function block data – Eaton Electrical PROFIBUS-DP EZ204-DP User Manual

Page 171

Advertising
background image

Read/write function block data

For more information visit: www.EatonElectrical.com

MN05013001E

167

Table 102: Operand overview

Table 103: Index 0 – Bit IO

Index
(hex)

Operand

Read

Write

00

Bit IO, J Table 103

×

01

Mode/Parameter

02

Upper threshold value

I1

×

c

1

03

Actual value of operating

hours counter

QV

×

1) The value can only be written if it is assigned to a constant in

the program.

Bit 7 6 5 4 3

2

1

0

FB input Data 1

– – – – –

RE

1

EN

2

FB output Data 3

– – – – –

Q1

3

1) Reset coil: Status 1 resets the counter actual value to zero.
2) Enable coil
3) Status 1 if the setpoint was reached (greater than/equal to)

J

The data for index 2 and 3 is transferred as a 32-bit value in

Intel format (Data 1 – Low Byte to Data 4 – High Byte).