43

MN05013001E

6

Control commands for EZ700

Data exchange procedure

The “Control commands 9 bytes” module allows extended

data exchange of the EZ700 on the PROFIBUS-DP

communication bus. This allows you to transfer services from

the following areas:
• Read/write image date and time (Page 45)
Read/write image data (Page 49) and
Read/write function block data (Page 72).

A data exchange procedure is required in order to ensure the

safe exchange of data via PROFIBUS-DP from master to

slave and vice versa.

Requirement:

The “Control commands 9 byte” module must have been

selected.

Attention!
While a control command is being executed, the input and

output data will remain in the state before the control

command was called. Only after the “Control commands”

data exchange has been completed, will the I/O data be

refreshed.

Caution!

Only those values specified for the command code should

be used.
Check the values that you write in order to avoid

malfunctions.