Mocomtech CDM-570 User Manual

Page 158

Advertising
background image

CDM-570/570L Satellite Modem with Optional IP Module

Revision 4

Front Panel Operation

MN/CDM570L.IOM

6–34

If the user selects Active, then a Receive Traffic fault will be generated
whenever the demodulator sees that the composite input level being
applied will cause compression in the IF stages, and hence degrade the
performance of the demodulator.

Similarly, the user can mask an Eb/No, Receive AIS or Buffer alarm.

If the user selects Masked, no alarm will be generated.

If Reference is selected the following sub-menu will be displayed:


Select Active or Masked, using the ◄ ► arrow keys, then press ENTER.

If the user selects Active, then a Transmit Traffic fault will be generated
whenever the unit sees that a) External Reference is selected and b) there
is no signal activity at the external reference port. If the user selects
Masked, no alarm will be generated.


If BUC is selected the following sub-menu will be displayed:

Select Active or Masked, using the ◄ ► arrow keys, then press ENTER.

If the user selects Masked, no alarm will be generated.


If LNB is selected the following sub-menu will be displayed:

Select Active or Masked, using the ◄ ► arrow keys, then press ENTER.

If the user selects Masked, no alarm will be generated.


Reference Alarm:
Active Masked (

◄ ►,ENT)

BUC Alarm:
Active Masked (

◄ ►,ENT)

LNB Alarm:
Active Masked (

◄ ►,ENT)