Mocomtech CDM-570 User Manual

Page 256

Advertising
background image

CDM-570/570L Satellite Modem with Optional IP Module

Revision 4

Serial Remote Control

MN/CDM570L.IOM

13–22

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Initialize
Statistics
Pointer

ISP= None Command

only.

Resets internal pointer to allow RNS? queries to start at the
beginning of the statistics log.

ISP=
ISP#

N/A N/A

Rx Eb/No

N/A

4 bytes

Query only.
Unit returns the value of Eb/No, between 0 and 16 dB,
Resolution 0.1 dB.
Returns 99.9 if demod is unlocked.

Example EBN=12.3 (which is Eb/No = 12.3 dB)
For values greater than 16.0 dB, the reply will be: EBN=+016

N/A EBN? EBN=xxxx

(see description of
arguments)

Rx Signal
Level

N/A

4 bytes

Query Only.
Unit returns the value of the Rx signal level, in dBm, between –5
and –99 dBm, in the form: ccxx, where:
cc = code:

GT=Greater Than
LT=Less Than
== is equal to

xx = value (the ‘-‘ sign is implied)
Examples:

RSL=LT99 (Rx signal level is less than -99 dBm)
RSL===41 (Rx signal level is equal to -41 dBm)

N/A RSL? RSL=ccxx

(see description
of arguments)

Rx Frequency
Offset

N/A

6 bytes

Query only.
Unit returns the value of the measured frequency offset of the
carrier being demodulated, in the form sxxx.x, where:
s = sign (+ or - character)
xxx.x = value (range from

± 0 to ± 200 kHz, 100 Hz resolution)


Returns +999.9 if the demodulator is unlocked.

Example: RFO=+002.3 (which is + 2.3 kHz)

N/A RFO? RFO=sxxx.x

(see description
of arguments)

Buffer Fill
State

N/A

2 bytes

Query only.
Unit returns the value of the buffer fill state, between 1 to 99%.
Returns 00 if demodulator is unlocked.

Example: BFS=33 (which is 33%)

N/A BFS? BFS=xx

(see description
of arguments)

Advertising