Mocomtech CDM-570 User Manual

Page 257

Advertising
background image

CDM-570/570L Satellite Modem with Optional IP Module

Revision 4

Serial Remote Control

MN/CDM570L.IOM

13–23

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Rx BER

N/A

5 bytes

Query only.
Unit returns the value of the estimated corrected BER in the form
a.b x 10

-c

. First three bytes are the value. Last two bytes are the

exponent. Returns 99999 if the demodulator is unlocked.

Example: BER=4.8E3 (which is BER = 4.8 x 10

-3

)

N/A BER? BER=a.bEc

(see description
of arguments)

Redundancy
State

N/A

1 byte, value
of 0 or 1

Query only.
Unit returns the redundancy state of the unit, where
0=Offline
1=Online

Example: RED=1 (which is Online)

N/A RED? RED=x

(see description
of arguments)

Outdoor Unit
Comms Enable

ODU=

1 byte, value
of 0 or 1

Command or Query. CDM-570 Only
Enables or disables communications, via the FSK link, with a
Comtech EF Data transceiver (ODU), where:
0=Disabled
1=Enabled

Example: ODU=0 (selects Disabled)

ODU=
ODU?
ODU*
ODU#

ODU? ODU=x

(see description of
arguments)

Front Panel
Lockout

FPL=

1 byte, value
of 0 or 1

Command or Query.
Control the state of front panel lockout, where:
0=no lockout
1=front panel lockout active

Disable the lockout by either FPL=0, or by setting into local mode
using LRS=0 (response is LRS+ meaning FPL is disabled at the
same time)

ODU=
ODU?
ODU*
ODU#

ODU? ODU=x

(see description of
arguments)

Local/Remote
Status

LRS=

1 byte, value
of 0, 1 or 3

Command or Query.
Local/Remote status, where:
0=Local
1=Serial Remote
3 = Ethernet Remote
Example: LRS=1 (which is Serial Remote)

LRS=
LRS?
LRS*
LRS#
LRS+

LRS? LRS=x

(see description of
arguments)

Advertising