Mocomtech CDM-570 User Manual

Page 414

Advertising
background image

CDM-570/570L Satellite Modem with Optional IP Module

Revision 4

Appendix D

MN/CDM570L.IOM

14

For HDLC address [SMALL NETWORK] in hex <0x1 - 0xFE, enter = 0000>:

select 1

15

CDM-IP 2 Route Table should display the following:

Route Name Dest IP/SNet Bits Next Hop MultiCast State
Route001..[test 172.16.10.0/24 0x1 N/A toSat]

Set Remote HDLC IP Address to 192.168.1.2

At this point the basic configuration is over and you should be able to:

Ping PC 1 from PC 2 and vice versa
Ping CDM-IP 2 from PC 1 and vice versa
Pass any other data between the 2 PCs

1

From PC1

Ping 172.16.10.1 (CDM-IP 1)

Ping 172.17.10.2 (CDM-IP 2)

Ping 172.17.10.11 (PC 2)

2

From PC2

Ping 172.17.10.1 (CDM-IP 2)

Ping 172.16.10.1 (CDM-IP 1)

Ping 172.16.10.11 (PC 1)

D–10