3 rs-232, 4 basic protocol – Mocomtech CDM-570 User Manual

Page 236

Advertising
background image

CDM-570/570L Satellite Modem with Optional IP Module

Revision 4

Serial Remote Control

MN/CDM570L.IOM

13–2

Each target has a unique address, and each time the controller transmits, in a framed
‘packet’ of data, the address of the intended recipient target is included. All of the targets
receive the packet, but only one (the intended) will reply. The target enables its output
line driver, and transmits its return data packet back to the controller, in the other
direction, on the physically separate pair.

RS-485 (full duplex) summary:

• Two differential pairs - one pair for controller to target, one pair for target to

controller.

• Controller-to-target pair has one line driver (controller), and all targets have line-

receivers.

• Target-to-controller pair has one line receiver (controller), and all targets have

tri-state drivers.

13.3 RS-232

This a much simpler configuration in which the controller device is connected directly to
the target via a two-wire-plus-ground connection. Controller-to-target data is carried, via
RS-232 electrical levels, on one conductor, and target-to-controller data is carried in the
other direction on the other conductor.

13.4

Basic Protocol

Whether in RS-232 or RS-485 mode, all data is transmitted as asynchronous serial
characters, suitable for transmission and reception by a UART. In this case, the only
supported asynchronous character format is 8N1 (8 data bits, no parity, 1 stop bit). The
baud rate may vary between 2400 and 57600 baud.

All data is transmitted in framed packets. The controller is assumed to be a PC or ASCII
dumb terminal, which is in charge of the process of monitor and control. The controller is
the only device which is permitted to initiate, at will, the transmission of data. Targets are
only permitted to transmit when they have been specifically instructed to do so by the
controller.

All bytes within a packet are printable ASCII characters, less than ASCII code 127. In
this context, the Carriage Return and Line Feed characters are considered printable.

All messages from controller to target require a response (with one exception). This will
be either to return data which has been requested by the controller, or to acknowledge
reception of an instruction to change the configuration of the target. The exception to this
is when the controller broadcasts a message (such as Set time/date) using Address 0,