LSI 53C875A User Manual

Page 164

Advertising
background image

4-72

Registers

STD

Start DMA Operation

2

The LSI53C875A fetches a SCSI SCRIPTS instruction
from the address contained in the

DMA SCRIPTS Pointer

(DSP)

register when this bit is set. This bit is required if

the LSI53C875A is in one of the following modes:

Manual start mode – Bit 0 in the

DMA Mode

(DMODE)

register is set

Single step mode – Bit 4 in the

DMA Control (DCNTL)

register is set

When the LSI53C875A is executing SCRIPTS in manual
start mode, the Start DMA bit must be set to start
instruction fetches, but need not be set again until an
interrupt occurs. When the LSI53C875A is in single step
mode, set the Start DMA bit to restart execution of
SCRIPTS after a single step interrupt.

IRQD

IRQ Disable

1

Setting this bit disables the IRQ pin. Clearing the bit
enables normal operation. As with any other register
other than

Interrupt Status Zero (ISTAT0)

and

Interrupt

Status One (ISTAT1)

, this register cannot be accessed

except by a SCRIPTS instruction during SCRIPTS
execution. For more information on the use of this bit in
interrupt handling, see

Chapter 2, “Functional

Description.”

COM

LSI53C700 Compatibility

0

When the COM bit is cleared, the LSI53C875A behaves
in a manner compatible with the LSI53C700;
selection/reselection IDs are stored in both the

SCSI

Selector ID (SSID)

and

SCSI First Byte Received (SFBR)

registers. This bit is not affected by a software reset.

If the COM bit is cleared, do not access this register
using SCRIPTS operation as nondeterminate operations
may occur. (This includes SCRIPTS Read/Write
operations and conditional transfer control instructions
that initialize the SFBR register.)

When the COM bit is set, the ID is stored only in the
SSID register, protecting the SFBR from being
overwritten if a selection/reselection occurs during a DMA
register-to-register operation.

Advertising