Bit address operating register/scripts ram read – LSI 53C875A User Manual

Page 254

Advertising
background image

6-16

Electrical Specifications

Figure 6.12 64-Bit Address Operating Register/SCRIPTS RAM Read

Table 6.18

64-Bit Address Operating Register/SCRIPTS RAM Read

Symbol

Parameter

Min

Max

Unit

t

1

Shared signal input setup time

7

ns

t

2

Shared signal input hold time

0

ns

t

3

CLK to shared signal output valid

11

ns

CLK

(Driven by System)

FRAME/

(Driven by Master)

AD[31:0]

(Driven by Master-Addr;

LSI53C875A-Data)

C_BE[3:0]

(Driven by Master)

PAR

(Driven by Master-Addr;

LSI53C875A-Data)

IRDY/

(Driven by Master)

TRDY/

(Driven by LSI53C875A)

STOP/

(Driven by LSI53C875A)

DEVSEL/

(Driven by LSI53C875A)

t

1

t

2

t

3

Out

In

Byte Enable

Bus

Dual
Addr

Addr

Lo

Addr

Hi

Data

Out

t

1

t

1

t

1

t

2

t

2

t

2

t

2

t

1

t

1

t

3

t

3

t

3

t

3

In

CMD