Electrical Specifications

Table 6.42

SCSI-2 Fast Transfers 10.0 Mbytes (8-Bit Transfers) or 20.0 Mbytes
(16-Bit Transfers) 40 MHz Clock

Symbol

Parameter

Min

Max

Unit

t

1

Send SREQ/ or SACK/ assertion pulse width

30

ns

t

2

Send SREQ/ or SACK/ deassertion pulse width

30

ns

t

1

Receive SREQ/ or SACK/ assertion pulse width

22

ns

t

2

Receive SREQ/ or SACK/ deassertion pulse width

22

ns

t

3

Send data setup to SREQ/ or SACK/ asserted

24

ns

t

4

Send data hold from SREQ/ or SACK/ asserted

34

ns

t

5

Receive data setup to SREQ/ or SACK/ asserted

14

ns

t

6

Receive data hold from SREQ/ or SACK/ asserted

24

ns

Table 6.43

Ultra SCSI Transfers 20.0 Mbytes (8-Bit Transfers) or
40.0 Mbytes (16-Bit Transfers) Quadrupled 40 MHz Clock

1, 2

1. Transfer period bits (bits [6:4] in the

SCSI Transfer (SXFER)

register) are set to zero and the Extra

Clock Cycle of Data Setup bit (bit 7 in

SCSI Control One (SCNTL1)

) is set.

2. During Ultra SCSI transfers, the value of the Extend REQ/ACK Filtering bit (

SCSI Test Two

(STEST2)

, bit 1) has no effect.

Symbol

Parameter

Min

Max

Unit

t

1

Send SREQ/ or SACK/ assertion pulse width

15

ns

t

2

Send SREQ/ or SACK/ deassertion pulse width

15

ns

t

1

Receive SREQ/ or SACK/ assertion pulse width

11

ns

t

2

Receive SREQ/ or SACK/ deassertion pulse width

11

ns

t

3

Send data setup to SREQ/ or SACK/ asserted

12

ns

t

4

Send data hold from SREQ/ or SACK/ asserted

17

ns

t

5

Receive data setup to SREQ/ or SACK/ asserted

6

ns

t

6

Receive data hold from SREQ/ or SACK/ asserted

11

ns