AC Characteristics

6-9

6.3 AC Characteristics

The AC characteristics described in this section apply over the entire
range of operating conditions (refer to the

DC Characteristics

section).

Chip timings are based on simulation at worst case voltage, temperature,
and processing. Timing was developed with a load capacitance of 50 pF.

Table 6.12

and

Figure 6.6

provide external clock timing data.

Figure 6.6

External Clock

Table 6.12

External Clock

1

1. Timings are for an external 40 MHz clock.

Symbol

Parameter

Min

Max

Unit

t

1

Bus clock cycle time

30

DC

ns

SCSI clock cycle time (SCLK)

2

2. This parameter must be met to ensure SCSI timings are within specification.

25

60

ns

t

2

CLK LOW time

3

3. Duty cycle not to exceed 60/40.

10

ns

SCLK LOW time

3

6

33

ns

t

3

CLK HIGH time

3

12

ns

SCLK HIGH time

3

10

33

ns

t

4

CLK slew rate

1

V/ns

SCLK slew rate

1

V/ns

CLK, SCLK 1.4 V

t

1

t

3

t

4

t

2

Advertising