Chapter 7: Port Parameter Commands

122

Section I: Basic Operations

10mhalf

10 Mbps and half-duplex mode.

10mfull

10 Mbps and full-duplex mode.

100mhalf

100 Mbps and half-duplex mode.

100mfull

100 Mbps and full-duplex mode.

1000mfull

1000 Mbps and full-duplex mode.
(Applies only to 1000Base SFP
and GBIC modules. This
selection should not be used. An
SFP or GBIC module should use
Auto-Negotiation to set its speed
and duplex mode.)

Note

A 10/100/1000Base-T twisted pair port must be set to
Auto-Negotiation to operate at 1000 Mbps.

mdimode

Sets the wiring configuration of the port. This

parameter applies to twisted pair ports, and only
when a port’s speed and duplex mode are set
manually. If a port is autonegotiating its speed
and duplex mode, the MDI/MDIX setting is
established automatically and cannot be
changed. The options are:

mdi

Sets the port’s configuration to MDI.

mdix Sets the port’s configuration to MDI-X.

flowcontrol

Specifies the flow control on the port. Flow
control applies only to ports operating in full
duplex mode. When flow control is activated, a
port sends out a PAUSE packet whenever it
wants the end node to stop sending packets.
The options are:

disabled No flow control. This is the default

setting.

enabled

Flow control is activated.

fctrllimit

Specifies the number of cells for flow control. A
cell represents 128 bytes. The range is 1 to
7935 cells. The default value is 7935 cells.

backpressure

Controls backpressure on the port.
Backpressure applies only to ports operating in