Add log output – Allied Telesis AT-S63 User Manual

Page 230

Advertising
background image

Chapter 15: Event Log and Syslog Server Commands

230

Section II: Advanced Operations

ADD LOG OUTPUT

Syntax

add log output=

output-id

module=[all|

module

]

severity=[all|

severity

]

Parameters

output

Specifies the output definition ID number.

module

Specifies what AT-S63 events to filter. The available

options are:

all

Sends events for all modules. This is the

default.

module

Sends events for specific module(s). You

can select more than one module at a
time, for example, MAC,PACCESS. For a
list of modules, see Table 12, “AT-S63
Modules” on page 249
.

severity

Specifies the severity of events to be sent. The
options are:

all

Sends events of all severity levels.

severity

Sends events of a particular severity.
Choices are I for Informational, E for Error,
W for Warning, and D for Debug. You can
select more than one severity at a time (for
example, E,W). For a definition of the
severity levels, see Table 13, “Event Log
Severity Levels” on page 251. The de
fault
is I, E, and W.

Description

This command configures an output definition.

Note

This version of the AT-S63 management software supports only
syslog servers as output definitions.

There are two steps to creating a output definition from the command line
interface. The first is to create the definition using “CREATE LOG
OUTPUT” on page 232. With that
command you assign the definition an
ID number, the IP address of the syslog server, and other information.

Advertising