Allied Telesis AT-S63 User Manual

Page 247

Advertising
background image

AT-S63 Management Software Command Line Interface User’s Guide

Section II: Advanced Operations

247

Examples

The following command changes the IP address for output definition
number 5 to 149.55.55.55:

set log output=5 server=149.55.55.55

The following command modifies output definition number 6 to only send
messages from the RADIUS module of all severity levels:

set log output=6 module=radius severity=all

The following command changes the facility level and message format for
output definition 4. The facility level is changed to LOCAL1 (numerical
code 17) and the format to normal so that the messages include only
severity, module, and description:

set log output=11 facility=local1 syslogformat=normal

The following command changes syslog server definition 11 to send only
spanning tree and IGMP snooping events with a severity level of error or
warning:

set log output=11 module=stp,igmpsnooping severity=e,w

Advertising