Cajun P550/P880/P882 Switch User Guide

Configuring System Information

3-15

Figure 3-8. Power System Window

2. Refer to Table 3-3 and review the Power System dialog box

parameters:

* Note: You will only see 600W of available power displayed in

the Total System Power field even if you have three
power supplies installed. The switch only uses power
from two of the three power supplies. The third power
supply is a redundant power supply and is used only if
one of the other power supplies fails.

Displaying the
Power System
Statistics Using
the CLI

To display your switch’s power system statistics using the CLI, enter
the following command from the Priv mode:

> show system power

Refer to the Cajun™ P550™/P880/P882 Command Line Interface
Reference Guide for Version 5.0
for details about this command.

Table 3-3. Power System Dialog Box Parameters

Parameter

Definition

Power Supply

Identifies the power supply

Status

indicates whether the power supply is
detected.

Type

Describes the type of power supply
detected.

Total System Power

Displays the total system power in Watts.

Current Power Available

Displays the current power available.