Setting up snmp communities using the cli – Avaya Cajun P882 User Manual

Page 80

Advertising
background image

2-14

Chapter 2

Cajun P550/P880/P882 Switch User Guide

6. Select a security level from the Security Level pull-down

menu (refer to Table 2-4).

7. Select Enable from the Trap Receiver field pull-down menu.

Disable is the default

* Note: Select Enable only if you selected Specific from

the IP Address field.

8. Click APPLY to save your changes, or CANCEL to clear your

selection.

* Note: If you click Apply, the changes are saved in the

Running config only. The Startup config has not
changed. Therefore, these and other changes
will be lost if your switch goes down or if you
power it off.

To save these changes, you must copy the
Running config as the Startup configuration.
Refer to the section “Copying Configuration
Files" section later in this chapter.

Setting Up
SNMP
Communities
Using the CLI

To set the SNMP communities parameters using the CLI, enter the
following command:

> snmp-server community <string>{ro|rw |none}[{normal| admin}]

Refer to the Cajun™ P550™/P880/P882 Command Line Interface
Reference Guide for Version 5.0
for details about this command.

Read-Write with
Security Level
Set to admin

View and set all switch
parameters, including
community table.

N/A

None

Disable a string without
deleting it.

Access any switch
features.

Table 2-3. Access Level Field Optionscontinued

Access Level

Manager Can...

Manager

Cannot...

Table 2-4. Security Level Field Options

Option

Allows Access to...

normal

All switch configuration and reporting functions.

admin

All switch configuration and reporting functions, including
access to community configuration.

Advertising