Viewing network statistics using the cli – Avaya Cajun P882 User Manual

Page 497

Advertising
background image

Cajun P550/P880 /P882 Switch User Guide

Analyzing Network Performance Using RMON and Ethernet Statistics

19-7

Viewing
Network
Statistics Using
the CLI

To view network statistics using the CLI, enter the following
command in Priv mode:

cajun# show ethernet counters <cr|mod-num|mod-

swport-spec>

Refer to the Cajun™ P550™/P880/P882 Command Line Interface
Reference Guide for Version 5.0
for details about this command.

Jabbers

Jabbers indicate that devices on
the networks are sending
improper electrical signals.
Because Ethernet uses electrical
signalling to determine whether
or not it is okay to transmit, a
jabber condition can halt all
traffic on a segment.

Possible causes:

• Bad network interface card

• Repeater network with

looped traffic

Possible actions (respectively):

• Replace the network

interface card.

• Rewire network to remove

the loop.

Collisions
(half-duplex
links only)

Counts number of times that
packets have collided on the
network. Collisions increase as
network use of shared segments
increases. Therefore, if the
collision rate increases without
an increase of network use, it
might indicate a problem.
Guidelines for appropriate
collision rates are:

• 10 percent: Normal

collision rate for shared
Ethernet segment.

• 30 percent: Collisions begin

to interfere with
performance.

• 70 percent: Practical limit

for network to remain
functioning.

A full-duplex link should not
show collision activity. Collisions
are rare in a switched network,
unless your switched segments
attach to multiple ends stations
(a legal configuration option).

Possible causes:

• Busy network

• Broken adapter (not

listening before
broadcasting)

• Network loop

Possible actions (respectively):

• If you have multiple stations

on a switch segment,
reconfigure network into
segments with fewer
stations.

• Isolate each adapter to see if

the problem ceases.

• Activate spanning tree to

resolve loops automatically.

• Ensure that there are no

connections to the same
station where both
connections are
simultaneously active.

Table 19-1. Ethernet Interface Statistics Dialog Box Fields continued

Statistic

Indicates

Actions

Advertising