B.O. Mode

A Black Out will take out all intensities.

Action

Feedback

B.O.

A Black Out of all intensity outputs, except those
controlled by the Independents in Exclusive mode. A
red B.O. Indication will appear on the top of all
screens.

Freeze Mode

When the Output Mode switch is set to FREEZE, the output is "frozen" and will remain static until the
switch is set back to ON.

When the switch is set back to ON the output is loaded to the A field of the Main Playback. The
Sequence will also reposition to where it was when you activated Freeze.

Action

Feedback

Activate Freeze

All outputs will be "frozen", including moving
devices. You can work with all functions without
affecting the output*

Deactivate Freeze

The "frozen" output of Freeze is loaded to the A
field of the Main Playback**

*The complete output, including all Master Playbacks is loaded to Freeze.

**If all Masters are down when you exit Freeze, there is no change in the output on stage.

NOTE
If you set the Output mode switch to FREEZE before you start the
application, the output will not be updated until you move the switch to on.
This makes it possible to start without output and prepare the correct light
before activating it on stage.

This is indicated at the top of the screens with the text "FREEZE".