Model 200iP/250iP Motorcycle Pit Dynamometer Installation Guide

C H A P T E R 2
Routing Cables

2-34

R

OUTING

THE

P

ICKUP

C

ARD

AND

D

YNO

E

LECTRONICS

C

ABLES

1

Route the pickup card cable (P/N 66953002) from the CPI through the designated
pit conduit and over to the pickup card. Attach the cable to the pickup card.
Note: Be sure to keep the power and communications cables in different pit
conduits.

2

Route the 25-pin cable (P/N 42924251) from the dyno electronics input/output
module to the Breakout board. Refer to Figure 2-38 for Breakout board location.
Refer to “Dyno Electronics” on page 1-10 for the 25-pin cable location.

3

Route the 9-pin serial cable (P/N 42967090) from the dyno electronics CPU
Module to your computer. Refer to “Dyno Electronics” on page 1-10 for the
9-pin serial cable location.

Figure 2-36: Route the Pickup Card and Dyno Electronics Cables

PD035

pickup card

dyno

electronics

CPI

25-pin cable to

breakout board

9-pin cable to

computer

pickup card cable

25-pin

cable to

breakout

board

route communications cables

in designated conduit