6-12

Broadmore 1750 - Release 4.6

Electrical Installation

Power Supply Connections

Power Supply Connections

Optional AC Power Supply Connections

... 6-12

Broadmore Power Input Connector

... 6-14

Connecting –48 VDC Power

... 6-14

WARNING!

T

HE

INSTALLER

SHALL

ENSURE

THAT

ALL

POWER

CONNECTIONS

TO

THE

B

ROADMORE

1750

HAVE

AN

APPROVED

SERVICE

DISRUPTION

FEATURE

EXTERNAL

TO

THE

B

ROADMORE

1750

FOR

EMERGENCY

USE

. T

HIS

MAY

BE

A

FUSE

,

CIRCUIT

BREAKER

,

CORRECTLY

LABELED

SWITCH

,

OR

OTHER

APPROPRIATE

DEVICE

.

Optional AC Power Supply Connections

The optional redundant AC Power Supply Tray mounts in the rack directly below
the Broadmore 1750 chassis (see “AC Power Supply Tray” on page

4-8

). Each

40W power supply module in the tray converts voltage from 110/220 VAC (50-60
Hz) to –48 VDC. Each DC cable has pigtail wires for connecting –48 VDC power
to the Broadmore chassis.

1. Locate the AC power cord provided with each power supply module and

connect one end to the AC connector on the rear of each module.

2. Ensure the power switch on the front of each module is turned OFF and that

the AC power indicator (LED) does not light.

3. Connect each AC power cord to a facility 110 VAC power receptacle. Cords

may be connected to different AC sources for additional redundancy if desired.

4. Turn each power switch to the ON position. The green AC power indicator

(LED) should illuminate beside each switch to indicate normal operation.

5. Turn each module power switch to the OFF position and verify that the power

indicator is off.

6. Locate the DC power cord provided with each power supply module and

connect the plug to the DC connector on the rear of each module.

Advertising