Broadmore 1750 - Release 4.6

7-15

Configuration

CIP over ATM (RFC 1577)

This configures the Broadmore 1750. Some Broadmore 1750s may need routing table
additions to recognize and respond to the control station via the ATM subnetwork.

These Broadmore 1750s will be configured individually, based upon network
topology. Each unit may or may not have an Ethernet connection.

In the case of no Ethernet connection, the unit routes Ethernet traffic to the ATM by
default. The Ethernet gateway setting is a null field. Follow the sequence on the next
page to verify that no gateway is defined. Do this for each applicable Broadmore 1750
without an Ethernet connection.

Item

Description

ATM IP Address

Enter the IP address within the subnet. Set to all
zeros to disable CIP.

ATM Subnet Mask

The mask is the same for all Broadmore 1750s
on the network.

Server Address

The address of the server containing the LIS.
This may be a workstation on the ATM network
or ATM switch. Set to zero if you want to use
AAL5 PVCs for CIP instead of SVCs.

Peak Cell Rate

This controls the bandwidth allocation to RFC
1577 support.

Enable RIP

Normally disabled. Only set to Yes for router
operation as the CIP subnet server.

Select System Management

Select Configuration

Select System Services

Select Configure IP

Select Gateway 0.0.0.0 (correct if necessary)