Broadmore 1750 - Release 4.6

7-53

Configuration

Structured DS3 SAM

Table 7-9: Structured DS3 SAM Alarms

Automatic FEAC
Alarms

Activate/Deactivate

Activates or deactivates Far End Alarm and Control
Channel (FEAC) alarms. FEAC alarms can only be active
when the port is configured for C-bit parity framing.
Activate to detect and transmit RAI as applicable and detect
FEAC channel activate/deactivate commands

Service FEAC
Loopback

Activate/Deactivate

Activate sends a FEAC command to the far end service
equipment to go into service loopback. Deactivate sends a
FEAC command to go out of service loopback. Only active
when port is configured for C-bit parity.

Service AIS

Activate/Deactivate

Sends Alarm Indication Signal to the connected local
service equipment when activated.

Service Alarms

Options

LOS

Ignore/Major/Minor

LOF

Ignore/Major/Minor

AIS

Ignore/Major/Minor

Idle

Ignore/Major/Minor

RAI

Ignore/Major/Minor

FEAC

Ignore/Major/Minor

Line Code Violation

Ignore/Major/Minor

Excessive F-bit Errors

Ignore/Major/Minor

Excessive Parity Errors

Ignore/Major/Minor

Excessive C-bit Errors

Ignore/Major/Minor

Excessive FEBE Errors

Ignore/Major/Minor

Item

Options