Static routes, Static routes -16 – Carrier Access Broadmore 1750 User Manual

Page 130

Advertising
background image

7-16

Broadmore 1750 - Release 4.6

Configuration

Static Routes

Static Routes

Each Broadmore 1750 has an additional Ethernet route to support RFC 1577 unless it
is on the same Ethernet network as the master control station. Follow the steps below
to add this routing. For sample configuration with static routes, see “Sample Network
with RFC 1577 Configuration” on page

D-1

.

1. Connect to the Broadmore 1750 via the serial port and log-in using the default

user ID and password, SYSADMIN and INITIAL.

2. This will give you the prompt: Broadmore>

Enter route –a

↵ to display the current routing table.

3. Add a routing entry in the format

route add xxx.xxx.xxx.xxx yyy.yyy.yyy.yyy

where xxx.xxx.xxx.xxx is the destination IP address (control station)
yyy.yyy.yyy.yyy is the ATM subnet IP address of the Broadmore 1750 on the
Ethernet segment serving as the control station.

4. Enter savert

↵ to save this entry. The new routing entry is immediately

active.

5. Enter route –a

↵ to observe that the route has been added to the table.

NOTE:

You may enter route delete xxx.xxx.xxx.xxx yyy.yyy.yyy.yyy

to remove the entry from the routing table.

6. Enter cammi

↵ to return to CAMMI.

Repeat this procedure for each Broadmore 1750.