8-13

Maintenance and Troubleshooting

24-Hour Statistics

24-Hour Statistics

Statistics for the most recent 24-hour period are maintained for DS3 modules. Statistics
for each port are maintained in a file that may be transferred via FTP to a PC and
viewed, using a spreadsheet program such as Microsoft Excel. The files are in the
STATS directory, and named according to the following sequence:

STATS\DS3C1.STA
STATS\DS3C2.STA
STATS\DS3C3.STA
STATS\DS3F1.STA (and so on)

The C1 represents slot C port 1, C2 represents slot C port 2, and F1 represents
slot F port 1.

Statistics are maintained according to the following:

A file is created when a PVC or SVC is activated on a port.

Statistics for a port are not recorded after the associated PVC is released.

Statistics are PVC and SVC dependent. When a PVC or SVC is established on a
port previously in use, the old statistics are moved to a “discard directory” and
new statistics are maintained.

The discard directory only retains statistics for the most recently released PVC or
SVC on any given port.

Use a standard spreadsheet program (such as Excel) to open a statistics file. Adjust the
column widths as necessary to match the printer/paper size in use so that the data may
be displayed on a single sheet of paper.