Figure 8-3: APM Major Alarm Troubleshooting Flowchart

A P M M a j o r A l a r m T r o u b l e s h o o t i n g F l o w c h a r t

From 1

NIM Major Alarm?

CPU Failure ?

SAM Major Alarm?

Review Alarm

Summary and System

log- gather all pertinent

info and call Customer

Service

No

No

No

Yes

Yes

1A

Return to

1

1B

Use loopbacks to verify

alarm condition

Check following most likely
causes/correct as necessary:
-equipment cable connectors
-NIM configuration
-reseat NIM module
-replace NIM module

Alarm Clears?

Yes

No

1A

1B

Reset CPU from front

panel switch

Alarm Clears ?

Check following most likely causes/
correct as necessary:
-cable connector to CPU/CPU I/O
-reseat CPU/CPU I/O modules
-replace CPU

Yes

No

1B

Alarm Clears ?

1B

1A

Yes

No

Yes

-Use loopbacks to isolate
-Check equipment cables
-Check configuration
-Reseat module
-Replace module

Alarm Clears ?

No

Yes

1A