Integrated fan/alarm module replacement, Integrated fan/alarm module replacement -37, Caution – Carrier Access Broadmore 1750 User Manual

Page 225

Advertising
background image

Broadmore 1750 - Release 4.6

8-37

Maintenance and Troubleshooting

Integrated Fan/Alarm Module Replacement

5. Firmly press the new fan assembly into place so that it is fully seated. Tighten

both retaining screws (finger tight only).

6. Return the defective fan assembly for repair. Contact Customer Service for an

RMA number and procedures.

Integrated Fan/Alarm Module Replacement

The integrated fan/alarm module has two replaceable fuses. Follow the steps below to
replace a fuse.

1. Fuses and spares are located on the integrated fan/alarm module IOM accessed

from the chassis rear. Remove the rear cover to access the fuses.

2. Blown fuses are removed by pulling directly out.

3. Remove a spare fuse by pulling directly out. Insert the replacement fuse(s) in

reverse to the one(s) removed.

4. Obtain replacement spare fuse(s) locally. Use only 7.5 Amp (Bussman part #

GMT7.5) or equivalent.

CAUTION!

F

USES

ARE

ONE

-

TIME

USAGE

ITEMS

. I

F

THE

FUSE

BLOWS

A

SECOND

TIME

,

CIRCUIT

DAMAGE

MAY

BE

MORE

EXTENSIVE

,

AND

IT

MAY

BE

NECESSARY

TO

DISCONNECT

POWER

TO

THE

ENTIRE

B

ROADMORE

1750

CHASSIS

AND

REPLACE

THE

INTEGRATED

FAN

/

ALARM

MODULE

.

A

LL

CIRCUITS

WILL

EXPERIENCE

A

DISRUPTION

DURING

INTEGRATED

FAN

/

ALARM

MODULE

REPLACEMENT

.

Follow the steps below to replace an integrated fan/alarm module.

1. Ensure that a replacement module is available.

2. Remove the chassis front cover.

3. Loosen retaining screws at the top and bottom of the integrated fan/alarm

module card to be replaced.

4. Use the installed ejectors to unseat the integrated fan/alarm module card from

the midplane. This is done by simultaneously pushing up on the top ejector and
down on the bottom ejector.

Advertising