7-34

Broadmore 1750 - Release 4.6

Configuration

CPU Redundancy

System Log

The system log is unique to each CPU. Entries are sent from each CPU and copied
to the partner CPU. Each entry has a time stamp followed by an upper-case or
lower-case slot letter. An upper-case letter (Q or R) indicates that the message
originated from the current CPU. A lower-case letter (q or r) indicates that the
message originated from the partner CPU. Thus, an entry in one log with an upper-
case slot letter will have a similar entry in the other log with a lower-case slot letter.

IP Addresses

A Broadmore 1750 chassis may have one or two IP addresses (see “Ethernet IP
Configuration” on page

7-9

). The online CPU will have the primary address as

configured in the Config IP menu. The standby CPU will have the secondary
address as configured in the Config IP menu. If a CPU switchover occurs, the
newly online CPU will change its IP address to the primary IP.

The Broadmore 1750 may also be configured with an IP address for CIP over
ATM. This address is only valid for the online CPU.

If used, a LANE address is configured via the LANE Configure menu. LANE is
only valid for the online CPU.

Select Maintenance/Diagnostics

Select View System Log

Select System Management

Select Configure

Select System Services