CPU Redundancy

Release CPU Control

If desired, the online CPU can be made to release control (switch) to the standby
CPU by performing the following steps. The online CPU will then become the
standby CPU, and vice versa. This command may be used during maintenance
procedures.

Reboot Standby CPU

If desired, the standby CPU can be rebooted by performing the following steps.
This command may be used during maintenance procedures.

Install Single or Dual CPU

This configuration item only activates detection of the SNMP trap Standby CPU
missing
. If only one CPU is present, select Single CPU. If two CPUs are
installed, select Dual CPU.

Select Maintenance/Diags

Select Redundancy

Select CPU

Select Release CPU Control

Select Maintenance/Diags

Select Redundancy

Select CPU

Select Reboot Standby

Select Maintenance/Diags

Select Redundancy

Select CPU

Select Installed